Built-in WallHybrid BMS

A comfortable heating and cooling solution for minimalist architecture

Outputs more information
BIWW_050_100_11_BMS
  • With analog input for controlling the heating unit.
  • Thermoelectric motor connections are possible
  • With or without manual control
  • Efficient and effortless heating with the lowest water temperature
  • Energy-efficient non-condensing cooling in combination with any heat pump that can supply cooling water
  • Improves the seasonal efficiency of a heat pump
  • Helps condensing boilers operate at their lowest temperature and as efficiently as possible
  • From the designers of the first low temperature heater

Home Automation / Building Management System - BMS

  • With 0-10V analog input.
  • Without control panel: the speed of the fans is determined by the control signal
  • With control panel: user can choose from 3 positions, whereby the speed of the boosters is also determined by the control signal.
  • Automatic heating / cooling changeover is possible.
  • Valve control with thermoelectric motor possible.
  • 30 years warranty

Outputs

Built-In Wall Hybrid BMS Outputs

Height (H) [cm] Length (L) [cm] Type Control Voltage
wdt_ID wdt_created_by wdt_created_at wdt_last_edited_by wdt_last_edited_at Height (H) [cm] Length (L) [cm] Type Control Voltage Heating (75/65/20) [Watts] Heating (55/45/20) [Watts] Heating (45/35/20) [Watts] Heating (35/30/20) [Watts] Cooling (16/18/27) [Watts] Sound Pressure [dB(A)] Electric Power Consumption [Watts] Order Code
1 Katie 31/01/2025 03:08 PM Katie 31/01/2025 03:08 PM 20 60 10 3.54 842 482 307 186 117 26 4.8 BIWW 020 060 10 BMS
2 Katie 31/01/2025 03:08 PM Katie 31/01/2025 03:08 PM 20 60 10 4.93 901 516 329 199 125 30 5.4 BIWW 020 060 10 BMS
3 Katie 31/01/2025 03:08 PM Katie 31/01/2025 03:08 PM 20 60 10 10 1.066 610 389 236 148 40 6.8 BIWW 020 060 10 BMS
4 Katie 31/01/2025 03:08 PM Katie 31/01/2025 03:08 PM 20 70 10 3.17 1.030 589 375 228 143 26 5.5 BIWW 020 070 10 BMS
5 Katie 31/01/2025 03:08 PM Katie 31/01/2025 03:08 PM 20 70 10 4.57 1.104 632 403 244 153 30 5.9 BIWW 020 070 10 BMS
6 Katie 31/01/2025 03:08 PM Katie 31/01/2025 03:08 PM 20 70 10 10 1.320 756 481 292 183 41 7.9 BIWW 020 070 10 BMS
7 Katie 31/01/2025 03:08 PM Katie 31/01/2025 03:08 PM 20 80 10 2.91 1.214 695 443 269 168 26 6.3 BIWW 020 080 10 BMS
8 Katie 31/01/2025 03:08 PM Katie 31/01/2025 03:08 PM 20 80 10 4.31 1.304 746 475 289 181 30 6.8 BIWW 020 080 10 BMS
9 Katie 31/01/2025 03:08 PM Katie 31/01/2025 03:08 PM 20 80 10 10 1.574 901 574 348 218 41.8 9.1 BIWW 020 080 10 BMS
10 Katie 31/01/2025 03:08 PM Katie 31/01/2025 03:08 PM 20 90 10 2.74 1.396 799 509 309 193 26 6.7 BIWW 020 090 10 BMS


Composition of the order code​​​

Hover over the parts below to find out what they stand for​​​​​

BIWW 020 060 10 BMS

Standard Delivery

  • light and easily installed by one person. Delivered flat packed in 2 packages for ease of handling and storage
  • Low-H2O heat exchanger with wall brackets and fixing kit
  • air vent elbow 1/8” and drain plug 1/2”
  • separation wall dark grey lacquered (not suitable as finished casing)
  • easy to install fan unit with operation, control and 24VDC power supply
  •   This heater is not equipped with a condensation monitor. It has to be integrated into the installation (only for cooling).